Yamaha TMAX XP530E-A 2017 Service Manual page 618

Table of Contents

Advertisement

Check each switch for continuity with the digital circuit tester. If the continuity reading is incorrect, check
the wiring connections and if necessary, replace the switch.
ECA18520
NOTICE
Never insert the tester probes into the coupler terminal slots "a". Always insert the probes from
the opposite end of the coupler, taking care not to loosen or damage the leads.
TIP
• Before checking for continuity, set the digital circuit tester to "0" and to the "  " range.
• When checking for continuity, switch back and forth between the switch positions a few times.
The switches and their terminal connections are illustrated as in the following example of the ON/start
switch.
The switch positions "a" are shown in the far left column and the switch lead colors "b" are shown in the
top row.
The continuity (i. e., a closed circuit) between switch terminals at a given switch position is indicated by
"
".
There is continuity between Blue/White and Black when the switch is set to "ON".
a
A. XP530E-A
B. XP530-A/XP530D-A
Digital circuit tester (CD732)
90890-03243
Model 88 Multimeter with tachom-
eter
YU-A1927
b
L/W
B
L/W
B
ELECTRICAL COMPONENTS
a
8-227
b
L/W B
L/W
B
W/G B/W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmax xp530-a 2017Tmax xp530d-a 2017

Table of Contents