Check Clock Synchronization; Check For Translation Corruption - Avaya DEFINITY Server R Manual

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading G3rV4 and R5/6/7/8r to Avaya DEFINITY
Server R running Avaya MultiVantage Software
Check link status
1. Enter display communication-interface links and press
2. Note all administered links.
3. Type
Check the following fields for the values listed:
4. If any of the links are not up, take the necessary corrective action to restore
the link before continuing with the upgrade.

Check Clock Synchronization

1. Type status sync and press
good. If not, contact the network to resolve.

Check for Translation Corruption

1. Type newterm and press
following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing
the upgrade.
2. If R5r or earlier, execute the following commands and note the status:
2-20
Issue 5 October 2002
number and press
status link
Link Status = connected
Service State = in service
NOTE:
For Release 7 and later, the only way to determine if an ISDN-PRI
D-Channel is up is to
1. Type list signaling group and press
Note the signaling groups listed by number.
2. For each of the signaling groups listed, type status signaling
group <number> and press
Enter
list trunk-group
list hunt-group
list data-module
list integrated announcements (if any)
for each administered link.
RETURN
.
RETURN
to verify that the clock synchronization is
Enter
. If you do not get a login prompt and see the
.
RETURN
.
RETURN
555-233-115

Advertisement

Table of Contents
loading

Table of Contents