Duplicate System Software; Verify System Status - Avaya DEFINITY Server R Manual

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading Release 9/10r to Avaya DEFINITY Server R
running Avaya MultiVantage Software
Change Vector Directory Number administration
If the Message Server Name field on page 2 of the Vector Directory Number
form is msa, remove this administration
change vdn 5000
Messaging Server Name:
VDN Timed ACW Interval:
BSR Available Agent Strategy: 1st-found
Screen 1-11. Vector Directory Number form

Duplicate System Software

In case the upgrade fails for any reason:
1. Ensure that the customer's previous systems software is on site.

Verify System Status

1. Type display alarms and press
2. If there are alarms, take the necessary corrective actions.
3. Type display errors and press
4. Examine the error log and record any Error Code 18 alarm that identifies
existing busyouts. After the upgrade you will restore the busyouts as they
were.
5. Execute the following commands to see whether the switch has
administration:
— list station
— list trunk-group
— list hunt-group
— list data-module
— list announcements
If any command does not complete successfully, escalate the problem
immediately. After the upgrade you will check the same administration to ensure
that the translations are intact.
1-16
Issue 5 October 2002
VECTOR DIRECTORY NUMBER
AUDIX Name:
Return Destination:
BSR Application:
(Screen
1-11).
.
RETURN
.
RETURN