Convert to SCC EPN

Convert to SCC EPN
As you are wiring the PPN installation, label the MDF with the new PN number of
the SCC PPN. The STS software upgrade assigns the next PN number (after the
highest numbered PN in the Release 5/6si system) to the upgraded EPN.
Check Link Status
1. Enter display communication-interface links and press
2. Note all administered links.
3. Type status link number and press
Check the following fields for the values listed:
4. If any of the links are not up, take the necessary corrective action to restore
the link before continuing with the upgrade.
Disable TTI
NOTE:
Do this step only if the Terminal Translation Initialization (TTI) is enabled.
Make sure the ISDN is in service. If not, try to busy out and release the ISDN
D-channel/link to bring the ISDN trunks back into service.
1. Type change system-parameters features and press
2. On the second screen, set the Terminal Translation
Initialization (TTI) Enabled? field to n to de-activate the TTI
feature. If it is already set to n, cancel the command and skip step 3.
3. Type status tti and press
4. Repeat Step 3 until the TTI Background Task State field is
completed.
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
555-233-115
Link Status = connected
Service State = in service
NOTE:
For Release 7 and later, the only way to determine if an ISDN-PRI
D-Channel is up is to
1. Type list signaling group and press
Note the signaling groups listed by number.
2. For each of the signaling groups listed, type status signaling
group <number> and press
Enter
for each administered link.
RETURN
RETURN
.
RETURN
.
Issue 5 October 2002
.
RETURN
.
Enter.