Tape Drive: Lock To Spe A (High/Critical Reliability Only) - Avaya DEFINITY Server R Manual

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading G3rV4 and R5/6/7/8r to Avaya DEFINITY
Server R running Avaya MultiVantage Software
If Tone/Clock in SPE A is not active:
4. Type set tone-clock 1a and press
B to SPE A.
5. Type status port-network 1 and press
has moved to SPE A. Make sure the YELLOW LED on the active
Tone/Clock is flashing steady.
If the Tone/Clock has not migrated to the carrier A after 1 minute, then a
Tone/Clock problem exists. Refer to the TDM-CLK maintenance object to
resolve any problems.
6. Type status spe and press
For high or critical reliability systems:
The standby refreshes after 5 minutes. If the fields display something other
than the above, see the appropriate maintenance sections.
Tape Drive: Lock to SPE A
(High/Critical reliability only)
!
CAUTION:
Always wear a grounded wrist strap to ground yourself against electrostatic
discharge (ESD).
1. Move the SPE-SELECT switches to the left (SPE A) on both Duplication
Interface (DUPINT) circuit packs, one at a time.
2-24
Issue 5 October 2002
NOTE:
This takes 1 minute to complete. If the service state is incorrect,
repeat the command until this condition is met.
The Standby Refreshed field shows yes
The Standby Shadowing field shows on
The Standby Handshake field shows up
to move the Tone/Clock from SPE
Enter
to verify that the Tone/Clock
Enter
to check the health of the SPE.
Enter
555-233-115