Power Up SPE A

1. If there are two power supplies, restore power to the SPE by inserting the
power plug on the right side of the carrier then by inserting the power plug
on the left side of the carrier. If there is only one power supply, insert the
one power plug on the right side.
If high or critical reliability:
2. Monitor SPE A as it reboots by observing the LEDs and the terminal. It is
powered up when the YELLOW LED on the UN331B/C Processor circuit
pack flashes and other LEDs go out, which takes about 10 minutes.
Unlock DUPINT Switches (High/Critical
reliability only)
1. Move the SPE SELECT switches to the AUTO position one at a time.
Wait for System Handshake (High/Critical
reliability only)
After the memory circuit pack is replaced in the SPE:
1. Type status spe and press
For high or critical reliability only:
2. If the Standby Handshake field does not display up, retype status spe
and press
fields will not be up. If the handshake does not come up, refer to
Table'' on page
2-36
Issue 5 October 2002
The Standby Refreshed field shows no
The Standby Shadowing field shows off
The Standby Handshake field shows up
NOTE:
SPE A now contains the Avaya MultiVantage Software; however,
SPE B still contains the old software release.
. The Standby Refreshed and Standby Shadowing
Enter
2-5.