Complete the Upgrade
Retranslate Port Circuits
If port circuit packs in the G2 module control carrier were relocated in order to put:
A critical port circuit pack, requiring longer nominal battery holdover (such
as a DS1 or an Announcement circuit pack), in a port slot
A TN736, TN752, or TN755 power supply in port slots "18" and "19"
A TN776 or TN570 Expansion Interface in port slot "1"
A TN776 or TN570 in port slot "2" (for a second directly connected EPN)
of the new expansion control carrier, verify that they were retranslated during the
off-site software upgrade. If not, they must be retranslated now. Refer to
Administrator's Guide for Avaya MultiVantage Software for instructions on
performing the retranslations.
Re-enable TTI
NOTE:
Do this step only if you disabled TTI before the upgrade.
1. Type change system-parameters features and press
2. On the second screen, set the Terminal Translation
Initialization Enable field to y to re-enable the TTI feature.
3. Type status tti and press
4. Repeat the status command until the TTI Background Task State
reads completed.
Check Link Status
1. Type display communication-interface links and press
with the earlier status.
2. Type status link number and press
Enable Scheduled Maintenance
Type change system-parameters maintenance and press
scheduled daily maintenance.
Resolve Alarms
Examine the alarm log and resolve any alarms.
555-233-115
.
Enter
. Repeat this step for each link.
Enter
Issue 5 October 2002
.
Enter
. Compare it
Enter
. Enable the
Enter
5-59