Avaya DEFINITY Server R Manual page 247

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Complete the Upgrade
Boot the System
1. Connect the management terminal to the "TERMINAL" connector behind
PPN control carrier "A," or connect through Avaya Site Administration
(ASA).
2. Insert the translation cards in the TN794 faceplates.
3. At each EPN power distribution unit, set the main circuit breaker to ON.
4. At the PPN power distribution unit, set the main circuit breaker to ON.
5. The system performs the reset level 4 rebooting process, loading the
default system translations from the translation card. This takes 8 to 11
minutes.
6. Get the order number of the upgrade, and call the regional CSA to request
an "init" login so the right-to-use options can be enabled on the upgraded
system.
7. To use Access Security Gateway (ASG), see
Security
Install the License File
Pre-installation
1. Type save translation and press
After the translations have been copied (about 10 minutes), the system
returns an error code, which must be a zero; otherwise, the translations are
not copied.
2. Type reset system 3 and press
Wait until the system has completely reset before continuing.
3. If the system has IP endpoints registered, unplug the Ethernet cable from
the TN799 (C-LAN) circuit pack.
This disconnects (unregisters) all IP endpoints.
4. Type set time and press
Ensure that the system date and time are set correctly.
555-233-115
Gateway''.
.
Enter
Appendix C, ''Access
.
Enter
.
Enter
Issue 5 October 2002
5-55

Advertisement

Table of Contents
loading

Table of Contents