4.10.5 CR Active Damper Auto Adjustment
EXECUTION MODE
Normal Mode
PROCEDURE
1.
When any paper is loaded, remove it.
2.
Turn the printer ON.
3.
Start the Service Program and select
(Automatic).
4.
Click [Run] to execute the calibration of the CR active damper.
5.
If a completion message appears, click [OK].
6.
Click [Finish].
7.
Turn the printer OFF to finish the adjustment.
Figure 4-25. [CR Active Damper Adjustment] Screen
ADJUSTMENT
CR Active Damper Adjustment
CR Related Adjustments