SC-F9200 Series
Replaced or Repaired
Class
(Reattached) Part/Unit
Replacement
CR Timing Belt
After
replacement
Replacement
CR related
parts/units
CR Unit (CR Assy)
After
replacement
Replacement
APG Motor Assy
After
replacement
Replacement
PW Sensor
After
replacement
ADJUSTMENT
Table 4-1. Adjustment items and the order by repaired part
Required Operations
1
Replacement
2
Turn the power on in normal mode.
3
CR Belt Tension Check
4
APG function check
5
CR Scale Check
6
CR Active Damper Adjustment (Automatic)
7
CR Motor Measurement & Automatic Adjustment
8
Manual Uni-d adjustment
9
Manual Bi-d adjustment
1
Replacement
2
Turn the power on in normal mode.
3
CR Belt Tension Check
4
APG function check
5
CR Scale Check
6
CR Active Damper Adjustment (Automatic)
7
CR Motor Measurement & Automatic Adjustment
8
Head inclination manual adjustment (CR direction)
9
Head slant auto adjustment (PF direction)
10 PG Adjustment
11 Manual Uni-d adjustment
12 Manual Bi-d adjustment
1
Replacement
2
Turn the power on in Serviceman mode.
3
Reset the motor counter.
4
APG function check
1
Replacement
2
Turn the power on in Serviceman mode.
3
Reset the sensor counter.
Overview
Service
Jig
Media
Program
---
---
√
Tensimeter U-507
√
√
√
√
√
PGPP
√
PGPP
---
---
√
Tensimeter U-507
√
√
√
√
√
PGPP
√
PGPP
---
Thickness gauge
√
PGPP
√
PGPP
---
---
√
√
---
---
√
SE Group Confidential (Related Staff Only)
Revision C
Replaced
Reattached
Page
√
√
p. 159
√
√
√
√
p. 297
√
√
p. 301
√
√
p. 304
√
√
p. 305
√
√
p. 356
√
√
p. 325
√
√
p. 327
√
√
p. 200
√
√
√
√
p. 297
√
√
p. 301
√
√
p. 304
√
√
p. 305
√
√
p. 356
√
√
p. 314
√
√
p. 319
√
√
p. 306
√
√
p. 325
√
√
p. 327
√
√
p. 167
√
√
√
p. 293
---
√
√
p. 301
√
√
p. 204
√
√
√
p. 293
---
261