SC-F9200 Series
3.4.5.7 CR Scale
When replacing/removing this part, refer to
A D J U S T M E N T
R E Q U I R E D
Items and the Order by Repaired Part" (p260)
perform the specified operations including required adjustment.
Do not contaminate the surface of the CR Scale with ink,
C A U T I O N
fingerprints, skin oil, or any other dirt. And be extremely careful
not to scratch or damage the surface by letting it come in contact
with the main unit frames or any other things. Doing so may result
in malfunction of the CR Unit.
1.
Unlock the CR Unit.
(p98)
2.
Open the Right Maintenance Cover.
3.
Open the Left Maintenance Cover.
4.
Open the Front Cover.
5.
On the left side of the printer, remove the tension spring.
6.
Move the CR Unit to the left end.
7.
On the right side of the printer, disengage the CR Scale from the hook on the
frame.
When installing the CR Scale, confirm the following.
Attach one side with "L" print to the left side of the printer.
Attach one side with "R" print to the right side of the printer.
DISASSEMBLY & ASSEMBLY
"4.1.2 Adjustment
and make sure to
Groove
8.
Release the CR Scale from each hook of the four CR Scale Holders.
9.
Pull out the CR Scale from the CR Scale.
Disassembly and Assembly Procedure
- Left side -
Left Side
CR Scale
Tension spring
Hook
Figure 3-96. Removing the CR Scale
CR Scale Holders
Front Cover
Figure 3-97. Removing the CR Scale
SE Group Confidential (Related Staff Only)
Revision B
- Right side -
Hook
CR Scale Holder
CR Scale
Hook
157