Handling Fifo Overrun In Bt.656 Or Y/C Mode - Texas Instruments TMS320C64x DSP Reference Manual

Dsp video port/vcxo interpolated control (vic) port
Hide thumbs Also See for TMS320C64x DSP:
Table of Contents

Advertisement

8) Write to VCxCTL to:
9) Capture is enabled at the start of the first frame after VCEN = 1 and begins
10) If continuous capture is enabled, the video port begins capturing again at

3.10.1 Handling FIFO Overrun in BT.656 or Y/C Mode

In case of a FIFO overrun, the COVRx bit is set in VPIS. This condition initiates
an interrupt to the DSP, if the overrun interrupt is enabled (setting the COVR
bit in VPIE enables overrun interrupt).
The overrun interrupt routine should set the BLKCAP bit in VCxCTL and it
should reconfigure DMA channel settings. The DMA channel must be reconfi-
gured for capture of the next frame since the current frame transfer failed. Set-
ting the BLKCAP bit flushes the capture FIFO and blocks DMA events for the
channel. As long as the BLKCAP bit is set, the video capture channel ignores
the incoming data with exception of SAV and EAV codes but the internal counters
continue counting.
The BLKCAP bit should be cleared to 0 in order to continue capture. Clearing
the BLKCAP bit takes effect in the subsequent video field (DMA events are still
going to be blocked in the video field in which the BLKCAP bit is cleared.)
SPRU629
-
Set capture mode (CMODE = 00x for BT.656 input, 10x for Y/C input).
-
Set desired field/frame operation (CON, FRAME, CF2, CF1 bits).
-
Set sync and field ID control (VRST, HRST, FDD, FINV, VCTL1 bits).
-
Set 10-bit pack mode (10BPK bits), if 10-bit operation is selected.
-
Enable scaling (SCALE and RESMPL bits), if desired and using 8-bit
data.
-
Set VCEN bit to enable capture.
at the start of the first selected field. DMA events are generated as
triggered by VCxTHRLD1. When a selected field has been captured
(VCXPOS = VCXSTOP and VCYPOS = VCYSTOP), the F1C, F2C, or
FRMC bits in VCxSTAT are set and cause the CCMPx bit in VPIS to be set.
This generates a DSP interrupt, if the CCMPx bit is enabled in VPIE.
the start of the next selected field or frame. If noncontinuous field 1 and
field 2 or frame capture is enabled, the next field or frame is captured,
during which the DSP must clear the appropriate completion status bit or
further capture is disabled. If single frame capture is enabled, capture is
disabled until the DSP clears the FRMC bit.
Capturing Video in BT.656 or Y/C Mode
Video Capture Port