Description:
Display and connector output for the upper torque limit of all torque limits without offset.
Dependency:
See also: p1520, p1521, p1522, p1523, p1528, p1529
r1527

CO: Torque limit lower without offset / M_max low w/o offs

Access level: 3
Can be changed: -
Unit group: 7_1
Min:
- [Nm]
Description:
Display and connector output for the lower torque limit of all torque limits without offset.
Dependency:
See also: p1520, p1521, p1522, p1523, p1528, p1529
p1528[0...n]

CI: Torque limit upper scaling / M_max upper scal

Access level: 4
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for the scaling of the upper torque limit in p1522.
DANGER
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
NOTICE
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1529[0...n]

CI: Torque limit lower scaling / M_max lower scal

Access level: 4
Can be changed: T
Unit group: -
Min:
-
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
DANGER
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
NOTICE
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Calculated: -
Scaling: p2003
Unit selection: p0505
Max:
- [Nm]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max:
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max:
-
Parameters
7.2 Parameter list
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 6060, 6630,
6640
Factory setting:
- [Nm]
Data type: Unsigned32 /
FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6630
Factory setting:
1524[0]
Data type: Unsigned32 /
FloatingPoint32
Dynamic index: CDS, p0170
Function diagram: 6630
Factory setting:
1525[0]