Parameters
7.2 Parameter list
Note
Value = 2 is only possible for Control Units with RS485 as a field bus interface.
p2040

Fieldbus interface monitoring time / Fieldbus t_monit

G120X_USS
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0 [ms]
Description:
Sets the monitoring time to monitor the process data received via the fieldbus interface.
If no process data is received within this time, then an appropriate message is output.
Dependency:
See also: F01910
Note
p2040 = 0:
Monitoring is deactivated.
For p2030 = 2 (Modbus RTU) or p2030 = 5 (BACnet MS/TP) the following deviation applies:
Factory setting: 10000
p2042

PROFIBUS Ident Number / PB ident No.

G120X_DP
Access level: 3
Can be changed: T
Unit group: -
Min:
0
Description:
Sets the PROFIBUS ident number (PNO-ID).
SINAMICS can be operated with various identities on PROFIBUS. This allows the use of a PROFIBUS GSD that is
independent of the device (e.g. PROFIdrive VIK-NAMUR with ident number 3AA0 hex).
Value:
0:
1:
Note
Every change only becomes effective after a POWER ON.
r2043.0...2

BO: PROFIdrive PZD state / PD PZD state

G120X_DP,
Access level: 3
G120X_PN
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the PROFIdrive PZD state.
Bit field:
Bit
00
02
Dependency:
See also: p2044
Note
When using the "setpoint failure" signal, the bus can be monitored and an application-specific response triggered when
the setpoint fails.
744
SINAMICS
VIK-NAMUR
Signal name
Setpoint failure
Fieldbus operation
Calculated: -
Scaling: -
Unit selection: -
Max:
1999999 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max:
1
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: FloatingPoint32
Dynamic index: -
Function diagram: 9310
Factory setting:
1000 [ms]
Data type: Integer16
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned8
Dynamic index: -
Function diagram: 2410
Factory setting:
-
0 signal
FP
No
-
No
-
SINAMICS G120X converter

Advertisement

Table of Contents
loading

Table of Contents