Polycom SoundStructure C16 Design Manual page 691

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Key Held On IR
Remote—ir_key_held
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Infrared Remote Input
Virt Chans
Control
System Limits
Minimum: 0, Maximum: 255
Event Source
No
Description
When queried, this parameter returns the keycode value of the last key that was held on the IR remote. As
an event, a status message is generated at an interval of approximately 100 ms whenever an key is held
on the IR remote.
Set IR Remote Channel
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Infrared Remote Input
Virt Chans
Control
System Limits
Minimum: 0, Maximum: 15
Default
3
User limits
No
Supported
Event Source
No
Description
This parameter sets the channel ID that the specified IR input will respond to.
Polycom IR remotes can be configured to use different channel IDs so that multiple remotes can be used in
the same room to control different equipment without interfering with each other. By default, the Polycom IR
Polycom, Inc.
ID—ir_chan_id