Polycom SoundStructure C16 Design Manual page 591

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

PSTN Line
Voltage—pstn_line_voltage
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read-Only
Phys Chans
Analog Telephony Output
Virt Chans
Mono
System Limits
Minimum: -128, Maximum: 128
Event Source
No
Description
This parameter indicates the line voltage (in Volts) of the PSTN interface. The value is valid in both
on-hook and off-hook modes. The value can be positive or negative, indicating the polarity of the tip/ring
voltage. When the value changes sign, it indicates that a polarity reversal has occurred.
Examples
Command
get pstn_line_voltage
"Phone Out"
Polycom, Inc.
Response
val pstn_line_voltage
"Phone Out" 0
Description
Queries the pstn_line_voltage and returns the measured
value in Volts on the phone line "Phone Out". Note that
the phone out virtual channel name must be used, not the
phone in virtual channel name.
591