The following figure shows the initiation of a TCP/IP connection to a SoundStructure device at address
172.22.2.110 and port 52774 using a third party terminal program.
Initiation of TCP/IP Connection to SoundStructure Device
Once the control session has been initiated, commands may be sent to the device and command acknowl-
edgments received as shown in the following figure where a mute command is sent to the virtual channel
group "Mics".
set mute "Mics" 0
The command responses are received back and include the mute status for all virtual channels in the "Mics"
virtual channel group.
Received Command Responses
When there are multiple simultaneous control sessions to a SoundStructure system, the control session that
sends commands will also receive command acknowledgments for all of its commands. Other control ses-
sions will only receive command acknowledgments from a command entered from another control session
if a parameter value changes.
For example, if a control session queries the value of the mute status, only that control session will receive
the acknowledgment of the mute value. However if the control session changes the mute state, for example,
all control sessions will receive an acknowledgment.