Digital GPIO Array
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Digital General Purpose I/O Input, Digital General Purpose I/O Output
Virt Chans
Control Array
System Limits
Minimum: 0, Maximum: 2147483647
Default
0
User Limits
No
Supported
Event Source
Yes
Description
This parameter gets or sets the value of the digital gpio array. Writing an input has no effect and returns the
current value of the input.

Control Port Parameters

Set Authentication
Argument
Argument value
Channel Type
Global system
Value Type
String
Read/Write Mode
Write-Only
System Limits
Max String Length : 128
Event Source
No
Description
This parameter sets the authentication password. The default value for this parameter is "456". The settings
are permanently changed immediately after the command has been executed.