94
After restoring a default configuration, you need to restart the system to initiate.
The following is an example of restoring a default configuration of the system.
SWITCH(config)# restore factory-defaults
You have to restart the system to apply the changes
SWITCH(config)#

System Management

When there is any problem in the system, you must find what the problem is and its solu-
tion. Therefore, you should not only be aware of a status of the system but also verify that
the system is configured properly.
This section includes the following functions with CLI command.

Network Connection

IP ICMP Source-Routing
Tracing Packet Route
Displaying User Connecting to
MAC Table
Running Time of System
System Information
System Memory Information
Average of CPU Load
Running Process
Displaying System Image
Displaying Installed OS
Default OS
Switch Status
Tech Support
Network Connection
To verify if your system is correctly connected to the network, use the command, ping.
For IP network, this command transmits echo message to ICMP (Internet Control Mes-
sage Protocol). ICMP is internet protocol that notifies fault situation and provides informa-
tion on the location where IP packet is received. When ICMP echo message is received
at the location, its replying message is returned to the place where it came.
To perform a ping test to verify network status, use the following command.
Command
ping [IP-ADDRESS]
SURPASS hiD 6615 S223/S323 R1.5