NK8000 MP.4.60
NK8222, NK8223, NK8225
NK8231, NK8232, NK8235
Installation
Function & Configuration
Commissioning
Safety Regulations
Building Technologies
Fire Safety & Security Products

Advertisement

Table of Contents
loading

Summary of Contents for Siemens NK8000 MP.4.60

  • Page 1 NK8000 MP.4.60 NK8222, NK8223, NK8225 NK8231, NK8232, NK8235 Installation Function & Configuration Commissioning Safety Regulations Building Technologies Fire Safety & Security Products...
  • Page 3: Table Of Contents

    Table of contents   About this document......................5     Safety regulations ....................9     Country-specific standards...................9     Assembly and installation..................9     Commissioning and testing ................10     Disposal and recycling ..................10     Modifications to the system design and the products ........10  ...
  • Page 4     5.1.2 NE8000 hardware installation .............34     NK822x hardware installation................37     NK823x hardware installation................46     Software installation ..................52     Installation checklist....................52     Composer tool ....................52     Launching Composer ..................53     NW8202 IP configuration download tool ............54  ...
  • Page 5: About This Document

    Training program information including the Siemens intranet link  A complete list of all available DMS8000 documents  Instructions for how to obtain a document via the Siemens intranet using the  Siemens Asset Portal A map of relevant documents for each target audience group ...
  • Page 6 2. Click Search to start. 3. In the resulting area on the right, click on Contents link to show the list of search results. For more information such as Siemens news and announcements, visit the STEP Web portal at: https://workspace.sbt.siemens.com/content/00001123/default.aspx...
  • Page 7 For more information on creating flowcharts, printed material are indicated with an arrow see Flowcharts [→92]. and the page number, enclosed in brackets: [→92] Modification index Note: For versions more than four years old, please visit the Siemens Asset Portal. Version Date Notes A6V10062437_a_en 06.2013 NK8000 MP4.60.
  • Page 8 About this document A6V10062437_a_en 06.2010 NK8000 MP4.30: – New NK8231 CEI adapter, improved NK8232 and NK8235 functions (BACnet and I C I/O still not supported). – Network tunnelling for remote CS6 configuration on NK822x. A6V10062437_a_en 12.2009 NK8000 MP4.20-01: – NK8232 and NK8235 released with some limitations. A6V10062437_a_en 06.2009 NK8000 MP4.20:...
  • Page 9: Safety Regulations

    Country-specific standards Siemens Building Technologies products are developed and produced in compliance with the relevant international and European safety standards. This document provides warnings and recommendations specific to NK8000 products. Any additional country- specific or local safety standards and/or regulations that apply concerning project planning, installation, operation, and device disposal must also be taken into account.
  • Page 10: Commissioning And Testing

    Modifications to the system design and the products Note: Modifications to a system or to individual products may cause faults or malfunctioning. Please request written approval from Siemens Building Technologies and from any relevant authorities concerning intended system modifications and system extensions. Data privacy and protection Make sure that the configuration of the system complies with local data privacy and protection regulations.
  • Page 11: Introduction

    Introduction Data privacy and protection 2 Introduction The NK8000 family provides LAN/WAN adapter products for a safety and security network: The NK822x series (phased out).  The NK823x series.  The NK8237 Modbus Gateway.  NK822x series includes: NK8222 Ethernet port: LAN/WAN (CMSDL/IP, CEI-79) and Dial-up (CEI-79) ...
  • Page 12: Interactions

    Introduction Interactions Interactions The unit can be programmed to support interactions between the connected subsystems: when a specified message is received from a source subsystem, one or more commands are generated for a destination subsystem according to the programmed interaction logic. local network-wide Interactions can be...
  • Page 13: What's New

    Introduction What's new What's new Here is the list of modifications for new functions and software improvements. Section Modifications Front panel [➙ 25] NK823x vitality green LED: twice blinking if logging is running. SD card [➙ 32] NK823x units are equipped with a 16 GB SD card for network communication logging.
  • Page 14: System Limits

    System limits NS8210 driver system limits 3 System limits The following describes the system limits for the NK82xx units and the corresponding NS82xx drivers for DMS8000 (MM8000 and MK8000) systems. For detailed NK8000 Release information about supported subsystem software versions see the Notes (document n.A6V10062453.) NS8210 driver system limits...
  • Page 15: Nk822X System Limits

    System limits NK822x system limits NK822x system limits Network capabilities (upstream towards management system host) Ethernet IEEE 802.3, 10Base-T, half-duplex, no auto-sensing or auto-negotiation  Single host transport protocols:  – CEI 79-5 type A and B (optional FEAL 64-bit encryption) –...
  • Page 16: Nk823X System Limits

    System limits NK823x system limits NK823x system limits Network capabilities (upstream towards management system host) 2 Ethernet interfaces IEEE 802.3, 10/100 Base-T with auto-negotiation, half/full-  duplex with auto-sensing, auto-crossover (thus eliminating the need for crossover cables) Single host transport protocols: ...
  • Page 17 System limits NK823x system limits Interaction capabilities NK8232 and NK8235 provides programmable interaction programs, including single or multiple triggers (incoming events) and single or multiple effects (outgoing control actions). Interactions are only possible between locally connected subsystems. For supported subsystems see Interactions [➙ 12] ...
  • Page 18: Structure And Functions

    Structure and functions NK822x hardware 4 Structure and functions NK822x hardware The NK822x is composed of an electronic board (with optional plug-ins) installed in a compact and robust plastic box. NK822x Ethernet port (NK8223 in this example) 4.1.1 Front panel The front panel houses 9 LED’s.
  • Page 19: Internal Dip Switches

    Structure and functions NK822x hardware Diagnostics (LED yellow) Internal interface diagnostics: : status OK.  Blinking (1 flash) : missing or insufficient license.  Blinking (2 flashes) : trouble with the I C bus to I/O modules.  Blinking (3 flashes) : trouble with the LON interface.
  • Page 20: Internal Jumpers

    Structure and functions NK822x hardware 4.1.3 Internal jumpers The internal jumpers are used for: JP3: when closed, it disables the box tamper alarm.  JP6: when closed, it enables the LON termination resistor (100 Ω) for a doubly  terminated bus topology. NK822x internal DIP switch and jumpers Item Description...
  • Page 21: Lon Interface

    Structure and functions NK822x hardware Note: In all modules, the first serial port can be configured as an RS232 interface using connector COM1 or as an RS485 interface using connector CN4. All lines are fully RS232 compliant and have EMC/ESD protection. No galvanic isolation is provided;...
  • Page 22 Structure and functions NK822x hardware Item Name Function CD00251 Rev.A boards CD00251 Rev.B boards Service mode — — request Diagnostics Blinking if LON is faulty Blinking if LON is faulty (yellow) Node in use LED normally on LED normally on (red) Service mode LED normally on LED normally off...
  • Page 23: Ethernet Interface

    Structure and functions NK822x hardware The logical BACnet address of NK822x is fixed to 1. This address has to be con- figured in the CS6 Guarto using the tool SWE6 for Guarto MP3 (Node CerCom Bus, properties of node Management Station). Note: The physical LON addresses and the logical BACnet addresses must be unique in a LON-network.
  • Page 24: Nk823X Hardware

    Structure and functions NK823x hardware DF8090 Power Supply Supervision DF8090 is a module designed for monitoring a 12V DC power supply. It can detect the conditions listed below, shown on the DF8090 local panel and report them to NK822x, and in turn to management station (see the following): Mains failure (no 220VAC) ...
  • Page 25: Front Panel

    Structure and functions NK823x hardware NK823x Ethernet port unit (NK8235 in this example) 4.2.1 Front panel The front panel houses 9 LED’s. Left Side LED’s The five LED’s on the left side are, from top to bottom: Power (LED green) Power (hardware –...
  • Page 26: Internal Dip Switches

    Structure and functions NK823x hardware Blinking (2 flashes) : trouble with the I C bus to I/O modules.  Blinking (3 flashes) : not used  Blinking (4 flashes) : trouble with the serial/network interface.  Blinking (5 flashes) : trouble with DLL or RCLOCK file(s). ...
  • Page 27: Internal Jumpers

    Structure and functions NK823x hardware 4.2.3 Internal jumpers The internal jumpers are used for: X115: When closed, it disables the box tamper alarm.  Internal DIP switch and jumpers (NKM8001-A1 mainboard) Item Name Description S101 DIP-Switches Reset button Tamper switch X115 When closed, it disables the box tamper alarm.
  • Page 28: Serial Interfaces

    Structure and functions NK823x hardware Internal DIP switch and jumpers (NKM8001-A2 mainboard) Item Name Description S101 DIP-Switches Reset button Tamper switch X115 When closed, it disables the box tamper alarm. 4.2.4 Serial interfaces NK8231.2 NK8232.2 NK8235.2 : these models are equipped with two serial lines ...
  • Page 29: Lon Interface

    Structure and functions NK823x hardware 4.2.5 LON interface The NK823x Ethernet Ports do not have a LON interface and do not support CS6 Guarto intrusion detection systems (use NK822x instead). 4.2.6 Onboard I/O The NK823x main board is equipped with three digital inputs (X102) and one relay output (X101).
  • Page 30 Structure and functions NK823x hardware DF8040 DF8040 is a module providing 8 inputs, which can be normally open or normally closed and driven by dry contacts or open collector signals. DF8045 DF8045 is a module providing 4 supervised inputs (normally-closed balanced in-puts). DF8046 DF8046 is a module providing 4 supervised inputs (normally-open balanced inputs) designed for migration of CS100/DMS7000 Multiplexer systems with B1G030 line...
  • Page 31: Ethernet Interfaces

    Structure and functions NK823x hardware Note: Locally connected DF8000 I/O modules are only supported with NK823x with build state 10 or higher (NKM8001-A2 mainboard). For more information about the DF8000 Input/Output modules, including installation DF8000 Datasheet (document no.A6V10081184) DF8000 details, see documents ICC (document no.A6V10081388) 4.2.8 Ethernet interfaces...
  • Page 32: Sd Card

    Structure and functions NK823x hardware 4.2.10 SD card The NK823x main board is equipped with a 16 GB SD card. The SD card slot is located below the CPU module and can be accessed only by removing the plastic housing. The SD card can be used to log data about network communications (see Network Connectivity Guide , document no.A6V10359485).
  • Page 33: Hardware Installation

    Hardware installation NE8000 cabinets 5 Hardware installation There are various possible installation scenarios. Namely:  Installation of NK82xx in existing cabinets. a. DIN-rail mounting (typical) in plastic housing. b. Mounting of the NK82xx board in the control unit housing using card holders and mounting kits.
  • Page 34: Ne8000 Hardware Requirements

    Hardware installation NE8000 cabinets 5.1.1 NE8000 hardware requirements Environmental requirements The cabinets should always be installed in a clean and safe environment, away from dust, high temperature and humidity, vibrations and impacts. Conditions and power supply should match the specific requirements given in the Technical data section of the NK8000 datasheet.
  • Page 35 Hardware installation NE8000 cabinets The VAC power supply wires (1.5 mm ) should be connected as illustrated in Figure VAC power connection WARNING Careful attention should be paid to the correct connections of VAC power lines. Input VAC 1.5 mm wires Ground Phase...
  • Page 36 Hardware installation NE8000 cabinets WARNING When entering the metallic frame of the cabinet, wires should be protected by a self- extinguishing plastic cord guard (UL94-V2 flammability rating). (Not provided in the supply). Wiring (1) – Front view of cabinet (arrow indicates cut-out holes) Wiring (2) –...
  • Page 37: Nk822X Hardware Installation

    Hardware installation NK822x hardware installation NK8021 modem in NE8000 cabinet NK822x hardware installation Installation 1. Install the NK822x unit on the DIN rail. 2. Connect subsystems: – Subsystem lines using the standard RS232 interfaces on COM1 - COM4. Note: Only COM1 and COM2 are available on NK8222. –...
  • Page 38 Hardware installation NK822x hardware installation Top view Back 1 2 1 NK822x electrical interfaces (top view) Item Name Description — LON Status LEDs Ethernet Not used. Power and LON RS485 (in place of COM1) NK822x electrical interfaces (top view) Note: Connectors in Figure are valid for NK8222, NK8223 and NK8225.
  • Page 39 Hardware installation NK822x hardware installation Bottom view Serial RS232 interfaces Item Name Description COM 3 — COM 4 — COM 1 In place of CN4 COM 2 — Note: NK8222 and some NK8223/NK8225 configurations do not include COM3/COM4. Building Technologies A6V10062437_a_en Fire Safety &...
  • Page 40 Hardware installation NK822x hardware installation Power connections Power supply RS485-1 POWER SUPPLY DF8090 BATTERY 27Ah 12V Batt Vin = Voltage In Vout Vout = Voltage Out Batt = Battery NK822x power connections CN1: Ethernet connector A standard RJ45 connector connects Ethernet. Category 5 or 6 UTP cabling is best suited.
  • Page 41 Hardware installation NK822x hardware installation CN3: Power supply Power connections. Assignment + PWR Earth – PWR — — CN4 (NK822x) / X104 and X105 (NK823x): RS485 connectors RS485 connectors. Assignment + RS485 – RS485 COM 1 ... COM 4: RS232 connectors RS232 lines are connected to 9pin D-Sub connectors, female type.
  • Page 42 Hardware installation NK822x hardware installation See LON interface [➙ 21] for additional information. LON TP/FT-10 network segment characteristics. Characteristic Bus topology Free topology Max. cable length (UTP Cat.4) [m] 1,400 Termination 2 x 100Ω, 1/8W 1 x 50Ω, 1/8W at each end of at centre of segment segment Max.
  • Page 43 Hardware installation NK822x hardware installation C interface SIEMENS Power Com 1 Vital functions Com 2 MAINS Tamper Com 3 AC/DC Download Com 4 LOW BATT BATT FUSE Diagnostic DF8090 DF8040 DF8040 DF8020 NK8223 1 2 3 4 5 6 7 8...
  • Page 44 Hardware installation NK822x hardware installation Installation in subsystem housing without DIN-rail NK82xx can be installed without the plastic box using the specific mounting kits for CS11/CS440 and SI410 (NK822x can also be installed in CS6). NK822x mounting option for CS11 AlgoRex CS11 EP7F Planning Note: For more details, see document no.
  • Page 45 Hardware installation NK822x hardware installation NK822x mounting option for CS6 Guarto NK822x mounting option for SI410420 Intrunet Building Technologies A6V10062437_a_en Fire Safety & Security Products 30.06.2013...
  • Page 46: Nk823X Hardware Installation

    Hardware installation NK823x hardware installation NK823x hardware installation Installation 1. Install the NK82xx unit on the DIN rail. 2. Connect subsystems: – Subsystem lines using the standard RS232 interfaces on COM1 - COM4. Note: Only COM1 and COM2 are available on NK8231 and NK8232. –...
  • Page 47 Hardware installation NK823x hardware installation X103 Power supply X104 RS485 (in place of COM1) X105 RS485 (in place of COM2) Bottom view Serial RS232 interfaces (bottom view) Item Name Description COM 3 — COM 4 — COM 1 In place of X104. COM 2 In place of X105.
  • Page 48 Hardware installation NK823x hardware installation Power connections Note the dual power supply input for redundant solutions. X103 X104 X105 Power supply RS485-1 RS485-2 POWER SUPPLY DF8090 BATTERY 27Ah 12V Batt Vin = Voltage In Vout Vout = Voltage Out Batt = Battery NK823x power connections WARNING There is a risk of explosion if the battery is replaced with an incorrect battery type.
  • Page 49 Hardware installation NK823x hardware installation Secondary (optional) Earth – X2/X3: Ethernet Connector A standard RJ45 connector connects Ethernet. Category 5 or 6 UTP cabling is best suited. Ethernet connections. Assignment TX– n.c. n.c. RX– n.c. n.c. X101: Onboard I/O (Output Relay) Onboard I/O (output relay).
  • Page 50 The I/O modules are mounted the same way. Note: Before removing the box, carefully disconnect the flat cable (bus) of the I module, as well as the power supply cables. C interface SIEMENS Power Com 1 Vital functions Com 2...
  • Page 51 Hardware installation NK823x hardware installation Installation in Subsystem Housing Without DIN-Rail NK8237 can be installed without the plastic box into the control unit cabinet. In this case, the NKA8011-A1 mounting plate may be needed. NK823x can be installed without the plastic box using the specific mounting kits available for CS11/CS440 and SI410.
  • Page 52: Software Installation

    Software installation Installation checklist 6 Software installation The software installation includes the following: Composer and basic tools for system configuration.  Additional tools: NW8202 (for IP configuration download) and NW8204 (for  maintenance and diagnostic). Installation checklist Items needed for the installation The DMS8000 DVD ...
  • Page 53: Launching Composer

    Software installation Launching Composer Launching Composer Do one of the following:  Launch Composer through the Start menu: Start > Programs > DMS8000 > Composer. Launch Composer by selecting the shortcut icon on your desktop, if available. When you start Composer for the first time, the following window displays: Composer server selection Note: To see this window every time you start Composer, deselect the Hide this dialog check box.
  • Page 54: Nw8202 Ip Configuration Download Tool

    Software installation NW8202 IP configuration download tool Note 1: To change a server connection at a later time, select the appropriate project or root node in the Projects Management window tree and then select the Change Projects Management window server icon (see figure Note 2: You cannot change a server connection while a project is open.
  • Page 55: Nw8202 Hardware Requirements

    Software installation NW8204 maintenance and diagnostic tool 6.4.1 NW8202 hardware requirements Pentium-class PC hardware or higher  Ethernet network interface adapter (IEEE 802.3, 10Base-T or 100Base-TX)  10 MB Free Disk Space  128 MB RAM (recommended)  6.4.2 NW8202 software requirements Windows XP Professional or higher operating system ...
  • Page 56: Nw8204 Hardware Requirements

    Software installation NW8204 maintenance and diagnostic tool Note: A similar maintenance and diagnostic tool is available on the Web. Note that the Web server tool is available only if the NS8210 driver is installed. For details see The NK8000 Web Server tool [➙ 79]. 6.5.1 NW8204 hardware requirements Pentium-class PC hardware or higher...
  • Page 57: Configuration

    Configuration Configuration checklist 7 Configuration After you have installed the Danger Management System (DMS) and Composer, you Installation Function & need to configure the DMS (follow product-specific Configuration Commissioning Guide Once that is done, you perform the configuration procedures to get the NK8000s communicating with the Danger Management System.
  • Page 58: Configuring Ip Settings Via Nw8202

    Configuration Configuring IP settings via NW8202 Configuring IP settings via NW8202 This configuration must be performed before the NK8000 can be configured at the client’s site. This procedure details how to send the IP configuration information; that is, the IP address, Subnet mask, and Default address to the NK8000 via the NW8202 Tool.
  • Page 59 Configuration Configuring IP settings via NW8202 NW8202 IP configuration download tool 8. Click Download.  The Download Procedure window is displayed. 9. Follow the instructions displayed. Note: On the NK823x unit, connect the network cable on Ethernet port 1. Note: Note the different dip-switch depending on the NK82xx model: set dip switch n.2 for NK822x and dip switch n.1 for NK823x.
  • Page 60 Configuration Configuring IP settings via NW8202 Back Ethernet connector on NK822x Back Connect Ethernet cables on NK823x  While the download is being performed, the FTP Diagnostic window is displayed with the current status of the download.  Once the operation has been performed, a final status notification and instruction window will be displayed.
  • Page 61 Configuration Configuring IP settings via NW8202 NW8202 final instruction window 10. Follow the instructions displayed in the final instruction window. Note: Set dip switch n.2 for NK822x and dip switch n.1 for NK823x. 11. Disconnect the NK82xx from the PC, and replace the cover. 12.
  • Page 62: Testing The Configuration

    Testing the configuration Checking the DMS - NK82xx connection(s) 8 Testing the configuration We recommend that you test connections during the configuration process so you can more easily narrow down the cause of any problems. This is because you may have problems in run-time where no error message is generated.
  • Page 63: Maintenance And Diagnostics

    Maintenance and diagnostics Kernel update 9 Maintenance and diagnostics Kernel update The NK823x Kernel is the main component of the operating system, which acts as a bridge between the application and the hardware level. In certain conditions, it may be necessary to update the Kernel, following specific instructions of the technical support.
  • Page 64: Snmp Monitoring

    Maintenance and diagnostics SNMP monitoring SNMP monitoring The NK823x units can support the SNMP protocol (Simple Network Management Protocol) to enable remote stations to monitor the units for conditions that may require administrative attention. Using the SNMPv1 (RFC 1155-1157) on the UDP port 161, the NK823x provides two sets of internal information variables using the community IDs listed here below that enable the access to the MIB (Management Information Base) namespace.
  • Page 65: The Nw8204 Maintenance And Diagnostic Tool

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool NW8204.exe Web browser NW8204 tool Server NS8210 NS8210 Web server TCP/IP NK8000 diagnostic tools This section details how to access and use these specialised tools to maintain and troubleshoot an NK8000 network and its components. Both tools have the same NW8204 functionalities.
  • Page 66: Launching Nw8204 From Dms Host

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Since the NW8204 maintenance tool is designed mainly for customer support / technical use, this guide covers only the most important features used for troubleshooting. You access the NW8204 tool by installing and then launching the application on the host DMS, or by launching the NK8000 Web Server application via Internet Explorer.
  • Page 67 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool NW8204 window (installed GUI) 2. Insert the NK IP Address. Note: Inserting an incorrect IP address causes the following window to appear. If you receive this message, select OK and re-type the IP Address. If you want to enter the NK8000 default IP address 192.168.9.41, you can use the menu Set Default IP Address instead of typing it.
  • Page 68 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool NW8204 window with open connection (installed GUI) Item Name Description Change User Select to display user login window (see step 1). Available through ‘Host’ menu in NK8000 Web Server NS8210 tool About Displays the version of the NW8204 tool.
  • Page 69: File Commands

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Download/Upload Transferred Bytes, Percent, and Byte/Sec rate. progress status Note: If you do not close the connection, you will automatically be timed out in five minutes. 9.4.2 File commands These commands are meant for remote technical maintenance and diagnostic of the NK8000 units.
  • Page 70 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Note: This function is only available when logged in as user “admin”. Set Date Time Opens a window for setting date and time and downloads the new settings to the RTC of NK8000.
  • Page 71 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Reads current settings of date and time from the NK8000 RTC. Read CPU ID Reads the CPU ID from the DIMM-PC module on NK822x. Read Product ID Reads the Product ID from the NK82xx. The Product ID is used to distinguish between NK8222, NK8223, and NK8225.
  • Page 72: Uploading Diagnostic Files

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Note: NK823x MP4.40 or later firmware is required. Read PIC24FW Ver Reads the PIC24 microcontroller firmware version. Note: NK823x MP4.40 or later firmware is required. Read WDT Status Reads the NK823x watchdog status (enabled or disabled). Note: NK823x MP4.40 or later firmware is required.
  • Page 73 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool This file is always present, and contains detailed technical information about the behaviour of the software application running on the NK8000. For example, if it wasn’t possible to open an internal queue during the initialisation phase, that message is saved to this file.
  • Page 74 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool EV_EEPROM_ETH_PNP_UPDATE Ethernet EEProm update EV_EEPROM_ETH_PNP_ERROR Ethernet EEProm update failed EV_EEPROM_DLL_LOAD_FAILED DLL load failure EV_EEPROM_DLL_EXCLUDED DLL excluded from round-robin schedule EV_EEPROM_DLL_OVERRUN DLL response time over threshold 1 EV_EEPROM_DLL_VER_ERR DLL version error EV_EEPROM_DLL_INIT_ERR DLL initialization error EV_EEPROM_DLL_OVERTIME DLL response time over threshold 2...
  • Page 75: Using Log Files

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool 3. Choose where you want to save the file(s) and select Save. 4. Select Close Connection. If you do not close the connection, you will automatically be timed out in five minutes.
  • Page 76 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Configuring the log upload Uploading log data Note: If the data upload procedure seems to require a too long time to be accomplished, you can abort the procedure by clicking the Abort Log Upload button. Note: The log file can be imported as CSV file in a spreadsheet application in order to be analyzed by expert users (Technical Support).
  • Page 77 Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Setting the log storage WARNING Removing the USB key while the logging is enabled (without using the Safely Remove command) may cause the unit to restart or block (a manual restart is then needed).
  • Page 78: Menu "Send Default Configuration File

    Maintenance and diagnostics The NW8204 maintenance and diagnostic tool Configuring logging function on the fly Note: Resetting the unit restores the original logging configuration saved in Composer. 9.4.6 Menu "Send Default Configuration File" Sends a default configuration file containing only the new IP-configuration to the NK8000.
  • Page 79: The Nk8000 Web Server Tool

    Maintenance and diagnostics The NK8000 Web Server tool Note: This function is only available when logged in as user “admin”. Note: Two download options are available in the Download Mode section: FTP (default) or Secure Download (encrypted data transmission that makes use of TCP port 20500).
  • Page 80 Maintenance and diagnostics The NK8000 Web Server tool Adding IIS 3. Select Details. 4. Select the FTP Server check box, then select OK. 5. Select Next. Note: You may be able to Browse to select where you want to store the utility. 6.
  • Page 81 Maintenance and diagnostics The NK8000 Web Server tool IIS security To increase the system security, IIS settings can be customized using the Microsoft Lockdown tool (http://technet.microsoft.com/en-us/library/dd450372.aspx). The tool must be installed and configured following the setup wizard, and allows for disabling all unnecessary IIS functions that may potentially become target of unauthorized access or even hacking attacks.
  • Page 82 Maintenance and diagnostics The NK8000 Web Server tool NK8000 Web Server startup window - Changing user Remote control commands The lower frame of the NS8210 utility window displays a list of NK82xx branches in the NK8000 networ. The following colour code applies: Green lines: NK823x units that are properly connected.
  • Page 83 Maintenance and diagnostics The NK8000 Web Server tool Send commands to a specific NK82xx by selecting the Commands icon and  clicking the command in the pop-up menu. The command list includes: – Build Identification: Start a CEI 97-5 identification procedure. –...
  • Page 84 Maintenance and diagnostics The NK8000 Web Server tool Filtering NK82xx branches Search and mark a specific NK82xx unit by selecting one of the searching options  and entering the value to search. Then, clicking Apply mark results in the corresponding NK82xx units being marked (Fig. 49). At that point, using the Marked branches filtering option allows for showing the selected unit only.
  • Page 85: Correcting Communication Failures

    Maintenance and diagnostics Correcting communication failures Searching and marking NK82xx branches by name Correcting communication failures 9.6.1 NK82xx generated a fault If an NK82xx generates a fault, there may be one or more causes. The problem may be in the NK82xx unit, or in the NK82xx connection to the DMS. Check the NK82xx Check power, vital function, and diagnostic state on the respective LED, which is located on the front panel of NK82xx.
  • Page 86: Control Unit Generated A Fault

    Maintenance and diagnostics Correcting communication failures 9.6.2 Control unit generated a fault If a control unit generated a fault, the problem may be in the connectivity between one of the control units (or subsystems) and the NK8000 . Check network connections CerCom/LON (CS6 Guarto only) ...
  • Page 87: No Fault Generated By Network Failure - Mp3.15 And Higher

    Maintenance and diagnostics Correcting communication failures Note: The LON Physical address: Subnet 01. Node 02 and the BACnet Logical Address 1 are reserved for the NK822x itself and must not be used for the Guarto. Check if the BACnet Logical Address for the management station in the CS6 Guarto configuration is set to 1 (To be checked with the CS6 tool SWE6 for Guarto in node CerCom Bus, properties of node Management Station).
  • Page 88: Secure Operation Requirements

    Compliance with local regulations must be addressed. This can concern paper listings as well as tapes and memory support. For further information on general security issues regarding Siemens products, please refer to the internal documentation and procedures on this subject.
  • Page 90 Issued by © 2013 Copyright Siemens Switzerland Ltd Siemens Switzerland Ltd Technical specifications and availability subject to change without notice. Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Document ID...

This manual is also suitable for:

Nk8222Nk8223Nk8225Nk8231Nk8232Nk8235 ... Show all

Table of Contents