Active Management Technology Support; Memory Configuration - Siemens SIMATIC IPC427E Operating Instructions Manual

Industrial pc firmware/bios description
Hide thumbs Also See for SIMATIC IPC427E:
Table of Contents

Advertisement

2.4.5

"Active Management Technology Support"

Calling "Active Management Technology Support"
Select: "Setup Usability (Page 9)" > "Advanced" > "Active Management Technology Support".
Firmware setting
Value
Intel AMT Configura-
Disabled
tion Screens
Enabled
Un-Configure ME
Disabled
Enabled
USB Configure
Disabled
Enabled
2.4.6

"Memory Configuration"

Calling "Memory Configuration"
Select: "Setup Utility (Page 9)" > "Advanced" > "Memory Configuration".
Firmware setting
Value
Max TOLUD
Dynamic
1 GB
1.25 GB
1.5 GB
1.75 GB
2 GB
2.25 GB
2.5 GB
2.75 GB
3 GB
Firmware/BIOS Description SIMATIC IPC427E, IPC477E
Operating Instructions, 07/2020, A5E50262994-AA
Setting in
Meaning
delivery
state
IPC427E
IPC477E
x
Active Management Technology BIOS Extension is enabled.
Active Management Technology BIOS Extension is disabled.
x
The settings for "Intel AMT Configuration Screens" must be re-
tained.
The settings for "Intel AMT Configuration Screens" must be re-
configured.
x
The USB configuration (USB Provisioning) from Intel®
Active Management Technology (iAMT) is disabled.
The USB configuration (USB Provisioning) from Intel® Active Man-
agement Technology (iAMT) is enabled.
Setting in
Meaning
delivery
state
IPC427E
IPC477E
The maximum value of TOLUD (Top Of Low Usable DRAM) is set.
With the "Dynamic" setting, TOLUD is automatically adjusted
based on the longest MMIO length of the installed graphics con-
troller.
x
Configure firmware
2.4 "Advanced" tab
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc477e