Port Mirroring
Fig. 5.2
To configure port mirroring, designate mirrored ports and monitor port. Then enable port
mirroring function. Monitor port should be connected to the watch program installed PC.
You can designate only one monitor port but many mirrored ports for one switch.
Step 1
Activate the port mirroring, using the following command.
Command
mirror enable
Step 2
Designate the monitor port, use the following command.
Command
mirror monitor {PORTS I cpu }
Step 3
Designate the mirrored ports, use the following command.
Command
mirror add PORTS [ ingress |
egress ]
Mode
Bridge
Activates port mirroring.
Mode
Bridge
Designates the monitor port.
Mode
Designates the mirrored ports.
Bridge
ingress: ingress traffic
egress: egress traffic