Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180
green
1. Use the green knife cassette
6GK1901-1GB01 (5.1 mm knife clearance)
in the stripping tool.
If your stripping tool was supplied with a
yellow knife cassette, the cutting depth must
be adjusted with the middle socket-head
screw after fitting the new cassette!
6. To strip the insulation, turn the tool in the
direction of the arrow
- approx. 4 times for PVC insulation,
- approx. 8 times for PUR insulation.
18
5
10. Spread out the wires according to the
color markings on the contact elements of
the connector.
11. Make sure to observe a length of
approximately 18 mm.
15. Close the cover by pressing together the
two halves of the lock. In doing so, make
sure not to exert pressure on or damage
the latch spring.
16. Turn the locking mechanism with your
hand as far as possible in the direction
of the arrow.
Copyright © 2017 Siemens AG
38mm
2. Take the stripping tool in your right hand.
3. Measure the cable length against the
measuring template. Use your left index
finger as the limit stop.
7. Keeping the stripping tool closed, pull it off
the end of the cable along with the jacket
and remnants of the shield.
12. Open the holder cover (e) until it latches
and push in the wires according to their
color coding* as far as the limit stop in
the holder cover
o
90
17. Insert a 2.5 mm screwdriver into the hole
in the locking mechanism and turn it as
far as the limit stop.
18. The connector is correctly locked when
the opening of the locking mechanism is
pointing to the side and the surfaces are
flush with the surface of the connector.
6GK1901-1BB10-2Axx
4. Insert the cable into the stripping tool. Your
left index finger is the limit stop.
5. Tighten the stripping tool fully.
8. If the white filler is not removed with the
insulation, remove it and the transparent
protective foil with your hand.
9. Cut off the dummy cores.
13. Push the cable into position as shown in
the picture (see arrows). Press down the
contact elements as far as the limit stop
to contact the wires.
14. Make sure the length of the cores
corresponds to the dimensions stated in
the assembly instructions for the
respective plugs.
19. Releasing the plug
Insert the plug into the socket and push
the spring down to unlock the plug and
release it from the socket again.
If space is limited, release the plug
using a screwdriver (2.5 mm-wide
blade).

Advertisement

loading

Summary of Contents for Siemens Simatic Net

  • Page 1 Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180 6GK1901-1BB10-2Axx 38mm green 1. Use the green knife cassette 2. Take the stripping tool in your right hand. 4. Insert the cable into the stripping tool. Your 6GK1901-1GB01 (5.1 mm knife clearance)
  • Page 2 When using devices without a securing collar, make sure to provide strain relief for the cable as closely as possible to the device. You will find information on network structures in the “SIMATIC NET Industrial Ethernet Networking Manual” or in the order overview.
  • Page 3: Simatic Net

    Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180 6GK1901-1BB10-2Axx SIMATIC NET Produktinformation A5E00328642-04 Product Information Stand / Dated 12/2017 Montageanleitung für / Assembly Instructions for SIMATIC NET Industrial Ethernet FastConnect RJ45 Plug 180 6GK1901-1BB10-2Axx Konfektionieren von/Assembling the 6GK1901-1BB10-2Axx an/with...
  • Page 4: Wichtiger Hinweis

    Wir weisen darauf hin, daß der Inhalt dieser Betriebsanleitung nicht Teil einer früheren oder bestehenden Vereinbarung, Zusage oder eines Rechtsverhältnisses ist oder diese abändern soll. Sämtliche Verpflichtungen von Siemens ergeben sich aus dem jeweiligen Kaufvertrag, der auch die vollständige und allein gültige Gewährleistungsregel enthält. Diese vertraglichen Gewährleistungsbestimmungen werden durch die Ausführungen dieser Betriebsanleitung weder erweitert noch beschränkt.
  • Page 5 Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180 6GK1901-1BB10-2Axx 38mm grün Verwenden Sie im Abisolierwerkzeug Nehmen Sie das Abisolierwerkzeug in Legen Sie die Leitung in das die grüne Messerkassette 6GK1901- die rechte Hand. Abisolierwerkzeug ein. Der Zeigefinger 1GB01 der linken Hand bildet den Anschlag.
  • Page 6 Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180 6GK1901-1BB10-2Axx Hinweise: Die Schneidklemm-Kontakte des Steckers Für die Herstellung eines Verbindungs-kabels Erneuern Sie die Messerkassette bei können bis zu 10 Mal gelöst und neu mit gekreuzten Adern kombinieren Sie an unsauberen Schnittergebnissen bzw.

This manual is also suitable for:

Fastconnect rj45 plug 1806gk1901-1bb10-2a series