Installing An Sfp Optical Port - Siemens RUGGEDCOM RX1511 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1511:
Table of Contents

Advertisement

Chapter 3
Communication Ports
Section 3.3.1, "Installing an SFP Optical Port"
Section 3.3.2, "Removing an SFP Optical Port"
Section 3.3.1

Installing an SFP Optical Port

To install an SFP optical port, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with
RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability
have not been properly assessed.
CAUTION!
Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated
before installing or removing components from the device. An electrostatic discharge (ESD) can cause
serious damage to the component once it is outside the chassis.
1.
Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic
discharges (ESD). This can be accomplished by wearing an ESD wrist strap or by touching Earth or the
chassis ground.
2.
Remove the dust cover from the port opening in the module.
CAUTION!
Mechanical hazard – risk of component damage. SFP optical ports are designed to insert in only
one orientation. Do not force the port into the module.
3.
Remove the port from its packaging.
4.
Insert the port into the module and swing the bail-latch up to lock it in place.
Figure 33: Installing an SFP Optical Port (Typical)
1. SFP Optical Port
5.
Remove the dust cover from the port.
6.
Connect a cable to the port and test the connection.
22
2. Metal Bail-Latch
1
2
RUGGEDCOM RX1511
Installation Guide
Installing an SFP Optical Port

Advertisement