Alcatel-Lucent 1643 AMS Operation Manual page 72

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
Encapsulated-MAC loss of frame alignment
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-52
EMACcLOF
Encapsulated Medium Access Control loss of frame alignment
Transmission
ethPS
Deferred
Reported
The red fault LED is lit. The WAN connection cannot operate successfully.
The alarm is raised when the GFP (or LAP-S, or EoS, depending on the
provisioning) frame synchronization is lost.
Check whether the VC cross-connection and/or mapping method are correct.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007

Hide quick links: