Alcatel-Lucent 1643 AMS Operation Manual page 332

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
Wrong 2 Mbit/s extension board present
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-312
E12XcWUP
A wrong extension board is present or the present extension board cannot be
identified.
Equipment
equipment
Prompt
Reported
The FAULT LED on the unit is lit.
Wrong extension board inserted, or the inserted extension board is defective.
Replace the extension board , and insert an extension board of the provisioned
type.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007