Alcatel-Lucent 1643 AMS Operation Manual page 230

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
Unit present in unassigned slot
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-210
UPUS
A unit is detected in a slot which has not been provisioned.
Equipment
equipment
Information
Reported
The red fault LED on the unit is lit.
A unit is installed but it has not (yet) been provisioned.
Have the unit provisioned, or
remove it from the indicated slot.
An empty slot, not configured, will not generate an alarm message.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007