Alarm messages
VC-12 Payload mismatch
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
VC12cPLM
The received payload value, used to indicate the composition of the VC-12
payload, does not match the expected value.
Transmission
sdhLOPath
Prompt
Reported
In the reporting Network Element:
In the downstream direction the alarm indication signal is inserted.
In the upstream direction VC-12 Remote Defect Indicator (RDI) is inserted.
The payload composition of the VC-11 is not as expected.
If the received V5 signal label (V5 [5-7]) has a value other than "000" or
"001", then check if the mapping mode of the local and far-end nodes is the
same.