Alarm messages
VC-11 Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
VC11cRDI
A Remote Defect Indication (RDI) is being received.
Transmission
sdhLOPath
Information
Not Reported
–
The downstream far end station of the node that reported the alarm detects a
malfunction at its receive side: VC- 11 Path trace identifier mismatch or
tributary unit alarm indication signal received.
No alarms in the reporting node. React on the far-end alarms. Follow the
clearing actions for those alarm(s).