Alcatel-Lucent 1643 AMS Operation Manual page 115

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
P12s Near- end background block errors threshold crossing
24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
P12SNBBEcTHR24
The P12s near-end background block errors counter exceeded the provisioned
threshold during a 24-hour monitoring period (PDH -> SDH).
Quality of service (performance monitoring)
pdhPath
Information
Not Reported
Equipment fault(s) in the upstream station.
Check upstream external cabling or equipment.
Alcatel-Lucent - Proprietary
See notice on first page
1-95