Alarm messages
"Monitored" (MON)
"Automatic" (AUTO)
"Not monitored"
(NMON)
Port monitoring mode
The monitoring mode of a physical port can be set for each port individually to:
• "Automatic" (AUTO),
• "Monitored" (MON), or
• "Not monitored" (NMON).
RS and MS termination point monitoring mode
Regenerator Section (RS) and Multiplex Section (MS) termination points have the
same monitoring modes as their associated physical interface (= physical port).
VC trail termination point monitoring mode
The monitoring mode of a VC trail termination point (TTP) can be set for each TTP
individually to:
• "Monitored" (MON), or
• "Not monitored" (NMON).
VC-Xv path termination point monitoring mode
The monitoring mode of a VC-Xv trail termination point (TTP) can be set for each
TTP individually to:
• "Monitored" (MON), or
• "Not monitored" (NMON).
P11s and P12s path termination point monitoring mode
The monitoring mode of a P11s or P12s trail termination point (TTP) can be set for
each TTP individually to:
• "Monitored" (MON), or
• "Not monitored" (NMON).
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Monitoring is enabled. The port or termination point provides service, and
the incoming port or termination point signal is monitored for defects. This
means that receive and transmit side signals are processed according to the
provisioning of the port or termination point, including alarm supervision
and performance monitoring.
A port or termination point can be put into this mode when the signal
source in the remote system is not (yet) operational.
Monitoring is disabled as long as no receive- and transmit-side signals are
applied. However, the monitoring mode is automatically switched to
monitored as soon as a signal is continuously applied.
A port or termination point can be put into this mode when it is not used.
Monitoring is disabled, the incoming port or termination point signal is not
monitored for defects.