Alcatel-Lucent 1643 AMS Operation Manual page 245

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
VC-12 Excessive BIP2 bit error rate
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
VC12cEXC
VC-12 signal degrade protected. The block error rate of an incoming VC-12
signal exceeds an error threshold in a protected configuration.
Transmission
Prompt
Reported
Fault(s) in upstream external cabling or equipment.
Check upstream external cabling and equipment.
Threshold is not provisionable.
Alcatel-Lucent - Proprietary
See notice on first page
1-225