Alcatel-Lucent 1643 AMS Operation Manual page 288

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
VC-3 Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-268
VC3cRDI
A Remote Defect Indication (RDI) is being received.
Transmission
sdhLOPath
Information
Not Reported
The downstream far end station of the network element that reported the alarm
detects a malfunction at its receive side: VC-3 Excessive error rate, VC-3 Path
signal label mismatch, or tributary unit alarm indication signal received.
No alarms in the reporting network element. React on the far-end alarms.
Follow the clearing actions for those alarm(s).
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007