Alarm messages
VC-3 Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-268
VC3cRDI
A Remote Defect Indication (RDI) is being received.
Transmission
sdhLOPath
Information
Not Reported
–
The downstream far end station of the network element that reported the alarm
detects a malfunction at its receive side: VC-3 Excessive error rate, VC-3 Path
signal label mismatch, or tributary unit alarm indication signal received.
No alarms in the reporting network element. React on the far-end alarms.
Follow the clearing actions for those alarm(s).
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007