Alarm messages
VC-12 Virtual concatenated loss of partial capacity
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-246
VC12VcLOPC
The transport capacity of the VC-12 Virtual Concatenation Group (VCG) is
partially unavailable.
This alarm will only be reported when LCAS is enabled.
Transmission
sdhVCG
Prompt
Reported
–
One or more VC-12s of the VCG have failed.
Identify the affected VC-12s by means of the alarms that are reported for these
individual VC-12s (VC12cEXC, VC12cDEG, VC12cTIM or VC12cUNEQ for
example), and clear these alarms.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007