Alarm messages
X21 interface extension board removed
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-322
X21XcUNI
X.21 interface extension board is missing.
Equipment
equipment
Prompt
Reported
The red "Fault" LED is lit.
Although the 1643 AM/ 1643 AMS is provisioned to be equipped with an X.21
interface extension board, no X.21 interface extension board is present.
Install an X.21 interface extension board, or change the provisioning.