Alcatel-Lucent 1643 AMS Operation Manual page 287

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
VC-3 Payload mismatch
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
VC3cPLM
The received payload value, used to indicate the composition of the VC-3
payload, does not match the expected value.
Transmission
sdhLOPath
Prompt
Reported
In the reporting Network Element:
The red fault LED is lit.
In the downstream direction the alarm indication signal is inserted.
In the upstream direction VC-3 Remote Defect Indicator (RDI) is inserted.
Payload composition of VC-3 at the network element that reported the alarm is
not the same as the payload composition of VC-3 at its far-end station.
If the received payload is >=1, check if the mapping mode of the local and
far-end network elements is the same.