Alarm messages
VC-3 Moderate block error rate
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-256
VC3cDEG
VC-3 signal degrade. The block error rate of an incoming VC-3 signal exceeds
an error threshold. The signal degrade threshold can be provisioned via the
management system.
Transmission
sdhLOPath
Deferred
Reported
Fault(s) in upstream external cabling or equipment.
Check upstream external cabling and equipment.