Alcatel-Lucent 1643 AMS Operation Manual page 126

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
P12s Near- end unavailable seconds threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-106
P12SNUAScTHR15
The P12s near-end unavailable seconds counter exceeded the provisioned
threshold during a 15-minute monitoring period (PDH -> SDH).
Quality of service (performance monitoring)
pdhPath
Information
Not Reported
The alarm was generated because of a fiber cut or equipment fault(s) in the
upstream station.
Check upstream external cabling or equipment.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1643 am

Table of Contents