Alarm messages
STM-1 MS Near-end unavailable seconds threshold crossing
24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-180
MS1NUAScTHR24
The STM-1 Multiplex Section near-end unavailable seconds counter exceeded
the provisioned threshold during a 24-hour monitoring period.
Quality of service (performance monitoring)
sdhMS
Information
Not Reported
Possible causes are:
Dirty optical connector(s).
Fiber cut.
Equipment fault(s) in the upstream station.
Check upstream external cabling or equipment.