Alarm messages
Wrong STM-1 interface extension board present
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-318
STM1XcWUP
An STM-1 interface extension board is provisioned, but an extension board of
a different type is present, or the present extension board cannot be identified.
A proper downloading of the software will not be possible.
Equipment
equipment
Prompt
Reported
The red "Fault" LED is lit.
Wrong extension board inserted, or the inserted extension board is defective.
Insert an STM-1 interface extension board, or change the provisioning.