Alcatel-Lucent 1643 AMS Operation Manual page 339

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
Wrong X21 interface extension board present
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
X21XcWUP
An X.21 interface extension board is provisioned, but an extension board of a
different type is present, or the present extension board cannot be identified.
A proper downloading of the software will not be possible.
Equipment
equipment
Prompt
Reported
The red "Fault" LED is lit.
Wrong extension board inserted, or the inserted extension board is defective.
Insert an X.21 interface extension board, or change the provisioning.
Alcatel-Lucent - Proprietary
See notice on first page
1-319

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1643 am

Table of Contents