Alarm messages
STM-1 MS Near-end unavailable seconds threshold crossing
15-min
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
MS1NUAScTHR15
The STM-1 Multiplex Section near-end unavailable seconds counter exceeded
the provisioned threshold during a 15-minute monitoring period.
Quality of service (performance monitoring)
sdhMS
Information
Not Reported
Possible causes are:
Dirty optical connector(s).
Fiber cut.
Equipment fault(s) in the upstream station.
Check upstream external cabling or equipment.