Alarm messages
VC-11 Payload mismatch
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-222
VC11cPLM
The received V5 signal label, used to indicate the composition of the VC-11
payload, does not match the expected value.
Transmission
sdhLOPath
Prompt
Reported
–
The payload composition of the VC-11 is not as expected.
If the received V5 signal label (V5 [5-7]) has a value other than "000" or
"001", then check if the mapping mode of the local and far-end nodes is the
same.
When defining or changing a cross-connection this alarm will almost inevitably
come up as it is practically impossible to issue the changes at both sides at the
same moment.
In the reporting Network Element:
•
In the upstream direction VC-11 Remote Defect Indicator (RDI) is inserted.
•
In the downstream direction the alarm indication signal is inserted.