Alcatel-Lucent 1643 AMS Operation Manual page 335

Access multiplexer and access multiplexer small (formerly metropolis am and metropolis ams. release 1.0 through 7.2. alarm messages and trouble clearing guide
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

Alarm messages
Wrong LAN unit present
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
IPcWUP
®
A TransLAN
card (X4IP-V2 or X8PL) is configured, but a card of a different
type is present, or the present card cannot be identified.
A proper downloading of the software will not be possible.
Equipment
equipment
Prompt
Reported
Wrong option board inserted, or the inserted option board is defective.
®
Insert a TransLAN
card, or change the provisioning.
®
If a TransLAN
card is actually present when the alarm is reported, then the
®
TransLAN
card is defective and has to be replaced.
Alcatel-Lucent - Proprietary
See notice on first page
1-315