Alarm messages
STM-4 MS Remote defect indicator
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-198
MS4cRDI
The STM-4 receive signal contains MS- RDI.
Transmission
sdhMS
Information
Not Reported
The downstream equipment has detected a receive signal failure, and has
inserted MS-RDI as a consequent action.
Locally no actions can be taken. Analyze the alarm state of the downstream
equipment and take appropriate measures.
The downstream equipment has detected one of the following failure conditions
at its receive side:
STM-4 MS AIS (Multiplex Section Alarm Indication Signal)
STM-4 LOS (Loss Of Signal) or
STM-4 LOF (Loss Of Frame).
This is reported to the transmitting equipment via the Remote Defect Indication
(RDI) which is used to draw local attention to the remote failure.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007