Alarm messages
2 Mbit/s output timing mode change
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-34
P12OTMcSW
The quality level of the clock used for retiming the 2 Mbit/s output signal has
no longer sufficient quality.
Transmission
pdhPath
Information
Reported
The quality of the system clock is not sufficient for re-timing purposes.
Restore the original timing source, or reconfigure the most reliable timing
source to improve the quality of the system clock, or change the threshold
quality alarm level.
The consequent action of this alarm is user provisionable (including but not
limited to switching from the re-timed to the self-timed mode).