Alarm messages
VC-11 Unequipped
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
Note(s)
...................................................................................................................................................................................................................................
1-224
VC11cUNEQ
VC-11 in STM-N signal not in use.
Transmission
sdhLOPath
Prompt
Reported
–
Cross-connections not consistently defined at both sides (for example, at local
and remote station) of a line section.
Define or change the cross-connections at the other side consistently with the
local side.
When defining or changing cross-connections this alarm will almost inevitably
come up as it is practically impossible to issue the changes at both sides
exactly at the same time.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007