Alarm messages
VC-4 Near-end unavailable seconds threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
1-292
VC4NUAScTHR15
The VC-4 near-end unavailable seconds counter exceeded the provisioned
threshold during a 15-minute monitoring period.
Quality of service (performance monitoring)
sdhHOPath
Information
Not Reported
Possible causes are:
Dirty optical connector(s).
Equipment fault(s) in the upstream station.
VC-4 is not reported.
Check upstream external cabling or equipment.
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2