Alarm messages
STM-4 RS trace identifier mismatch
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
RS4cTIM
The received section trace identifier, used to verify the continued connection to
the intended transmitter, does not match the provisioned value.
Transmission
sdhPRS
Prompt
Reported
Possible causes of the alarm are:
Wrong routing somewhere in the network due to wrongly provisioned
cross-connections or wrongly connected line cables.
Wrongly configured expected trace identifier filled in via the management
system for the node that reported the alarm.
Wrongly configured transmitted trace identifier in the remote equipment.
Check the correctness of the expected RS trace identifier in the local
equipment.
Check the correctness of the transmitted trace identifier in the remote
equipment.
Check the correctness of the cross-connections.
Determine in which node(s) the line cables are wrongly connected by
interpreting the received STM-4 RS trace identifiers.
Alcatel-Lucent - Proprietary
See notice on first page