Alarm messages
45 Mbit/s extension board removed
...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
E32XcUNI
The 45 Mbit/s extension board (X2DS3-V2) is missing.
Equipment
equipment
Prompt
Reported
The red fault LED on the unit is lit.
Although the respective slot is provisioned to be equipped with a 45 Mbit/s
extension board, no 45 Mbit/s extension board is present.
Install a 45 Mbit/s extension board, or change the provisioning (i.e. unassign
the slot).